What’s The Difference In 2026?
A Fire Safety Certificate in NSW is issued once, when building work involving fire safety measures is finished and an annual fire safety statement (AFSS) is issued every year after that. The certificate confirms new measures were installed and checked. The AFSS confirms an accredited practitioner has assessed every essential measure in an existing building (Planning NSW) (SSC).
Quick Summary
For NSW owners finishing a build, fit-out or council-ordered upgrade, the certificate is the one-off sign-off you need before anyone moves in. Your first AFSS is then due within 12 months. Watch the February 2027 change: certifying newly installed measures will need an accredited person.
Table Of Contents
Fire Safety Certificate Vs AFSS At A Glance
Both documents are about the same essential fire safety measures. They just look at them at different points in a building’s life.
| Question | Fire Safety Certificate (FSC) | Annual Fire Safety Statement (AFSS) |
| When it’s issued | Once, when building work involving fire safety measures is complete | Every year for an existing building |
| What it confirms | A properly qualified person installed and checked the measures listed in the fire safety schedule | An accredited practitioner (fire safety) assessed, inspected and verified each essential measure |
| Who issues it | The owner, or someone on the owner’s behalf | The owner, or someone on the owner’s behalf |
| What it’s needed for | Before an occupation certificate can be issued | Ongoing compliance, year after year |
| Assessment window | Within 3 months before the certificate is issued | Within 3 months before the statement is issued |
| Who gets a copy | FRNSW (with the current schedule); council receives it through the principal certifier | Council and FRNSW |
| Display | Prominently in the building, with the fire safety schedule | Prominently in the building |
| Form | NSW Government Fire safety certificate template | NSW Government Fire safety statement template |
What Is A Fire Safety Certificate In NSW?
A Fire Safety Certificate is the sign-off at the end of building work.
It’s issued by or on behalf of the owner when new building work is complete, and it says a properly qualified person has installed and checked the measures listed in the fire safety schedule (Planning NSW).
It isn’t only for brand new buildings. Councils also require one after works under a council fire safety order and on a change of use before the new use starts (BSC) (Mosman Council). If your building is under an order, our guide on what to do when you’ve Received A Council Fire Order covers that path.
The certificate matters because nothing moves without it. FRNSW says it’s required before an occupation certificate can be issued, and the building can’t be occupied until the principal certifier issues that occupation certificate.
Any Questions?
Our Experts Look Forward To Hearing From You!
Final Vs Interim Fire Safety Certificates
A final Fire Safety Certificate is issued when building work or a change of use is complete. In staged projects, a final certificate can be issued for part of a building.
Interim certificates are where you’ll find conflicting advice. Lake Macquarie Council describes an interim certificate as one usually issued with an application for an interim occupation certificate. Burwood Council says interim certificates are no longer permissible, because interim occupation certificates haven’t been issued since 2020. FRNSW’s lodgement page still lists both types. Our view: plan for a final certificate, and ask your principal certifier early if your project is staged.
What Is An Annual Fire Safety Statement?
An AFSS is the yearly check for an existing building. It must be issued each year, it covers every essential fire safety measure that applies to the building, and it confirms an accredited practitioner (fire safety) has assessed, inspected and verified the performance of each one (Planning NSW).
The owner, or someone on the owner’s behalf, issues it and lodges it with both council and Fire and Rescue NSW. A copy must also be displayed prominently in the building. For the full process, read our NSW Annual Fire Safety Statement Guide.
Supplementary Fire Safety Statements
Some buildings also need supplementary statements. These cover critical fire safety measures and are issued at shorter intervals, as set out in the fire safety schedule (Planning NSW). The assessment for a supplementary statement must happen within one month before it’s issued.
Is There An “Annual Fire Safety Certificate” In NSW?
No. People search for an “annual fire safety certificate” all the time, but NSW doesn’t issue one.
The yearly document is the annual fire safety statement. The certificate is the one-off document at the end of building work (Planning NSW).
This isn’t just a naming point. If a contractor quotes you for an “annual certificate”, ask which document they mean. You need the AFSS lodged every year, and a new Fire Safety Certificate only when work triggers one.
Not Sure What Your Fire Safety Schedule Requires?
Our Experts Look Forward To Hearing From You!
Which Buildings Need Each Document?
Both documents work from the building’s fire safety schedule. In practice, that means Class 1b to 9 buildings, small guest houses and hostels (Class 1b), apartment buildings (Class 2), offices (Class 5), shops and cafés (Class 6), carparks and warehouses (Class 7), factories (Class 8), and hospitals, schools and aged care (Class 9).
Source: NCC – Class Descriptions
Source: NSW Gov – Classes 1b to 9 & Maintenance
The schedule decides which measures each document covers. If you don’t have yours, start with our guide to the NSW Fire Safety Schedule.
Who Can Issue Or Assess Each One?
The owner issues both documents, or someone does it on their behalf. The difference is who checks the measures first.
| Document | Who Checks The Measures Today | What Changes |
| Fire Safety Certificate | A properly qualified person chosen by the owner | From 13 February 2027 (or 18 months after an accreditation scheme is approved, whichever is first), an accredited person must certify newly installed measures |
| Annual fire safety statement | An accredited practitioner (fire safety) | No change announced |
Source: RFNSW – FSC today
Source: NSW Gov – 2027 change
Source: Planning NSW – AFSS
The 2027 change is the one most owners haven’t heard about. It’s already been deferred once, from 13 February 2025, and the Building Commission says it will notify stakeholders when an accreditation authority and scheme are set up. Our NSW Fire Safety Regulation Changes article tracks it.
For AFSS assessments, the accreditation already exists. The Fire Protection Accreditation Scheme, developed by Fire Protection Association Australia (FPAA), was approved on 1 July 2020 and covers assessing essential measures for annual and supplementary statements. Accreditation isn’t needed to install or routinely maintain the measures.
Want To Know More?
Our Experts Look Forward To Hearing From You!
How The Certificate Starts Your AFSS Clock
Here’s what catches new owners. Your first AFSS is due within 12 months of the Fire Safety Certificate being issued. After that, each one is due within 12 months of the last (FPA).
The assessment behind the statement must be done within the three months before it’s issued, so you can’t do it too early either.
Worked example (illustrative only)
An office fit-out in a Class 5 building finishes and the Fire Safety Certificate is issued on 16 March 2026.
| Date | What Happens |
| 16 March 2026 | FSC issued. Owner sends a copy, with the current schedule, to FRNSW and displays both in the building |
| November 2026 | Owner books the accredited practitioner (fire safety) for a date after mid-December |
| 16 December 2026 | Earliest date the assessment can happen and still fall within three months of a 16 March 2027 statement |
| By 16 March 2027 | First AFSS issued, lodged with council and FRNSW, and displayed |
| By 16 March 2028 | Second AFSS due |
This ignores critical measures with supplementary statements, council-specific due dates and the time needed to fix any defects found (LCC) . Check your council’s records for your actual due date.
Leave room for defects. If the assessment finds a fault, it has to be fixed before the measure can be signed off. Booking at the start of the three-month window gives you time.
Ready To Discuss Your Requirements?
Our Experts Look Forward To Hearing From You!
What Drives The Cost Of Each
Costs depend on the building, so we don’t publish a price list. These are the main drivers.
| Cost Driver | Fire Safety Certificate | AFSS |
| Number and type of measures | Only the measures installed or altered by the work | Every essential measure on the schedule |
| Timing | Tied to the builder’s handover and the certifier’s occupation certificate | Fixed annual due date, so you can book ahead |
| Defects found | Commissioning faults delay sign-off | Repairs are needed before measures can be signed off |
| Critical measures | Not applicable | Extra supplementary statements during the year |
| Records | Installer documentation and test results | Logbooks and service history from routine maintenance |
The cheapest AFSS is usually the one where routine maintenance has been done properly all year. Our Guide To How Often Fire Systems Should Be Tested explains that side.
What Happens If You Skip The Certificate Or Miss Your AFSS?
Without a Fire Safety Certificate, the principal certifier can’t issue the occupation certificate, and the building or part can’t be lawfully occupied. That’s the immediate commercial hit: no handover, no tenants moving in (FRNSW).
Miss an AFSS and councils can act. Lane Cove Council warns that significant penalties apply when statements aren’t provided by the due date. Councils can also issue penalty notices and fire safety orders, and serious cases can go to prosecution. There’s insurance and liability exposure too if something goes wrong. Penalties vary by council area, so check with yours. Our article on Costly AFSS Mistakes covers how they usually happen.
Strata Vs Commercial Buildings
The rules are the same. What differs is how often work triggers a new certificate.
| Situation | Strata (Class 2) | Commercial (Classes 5 To 9) |
| Usual FSC trigger | Completion of the building, or common-property works involving fire safety measures | Tenant fit-outs, extensions and changes of use |
| Who organises the AFSS | The owners corporation, often through the strata manager | The building owner or their property manager |
| Common trap | Missing the first AFSS after handover from the developer | A fit-out FSC handled by the tenant’s builder that the owner never sees |
For strata-specific detail, see our guide to Fire Protection Requirements For Strata Buildings.
When You Don’t Need A New Fire Safety Certificate
A certificate follows building work involving fire safety measures, a change of use, or works under a fire safety order. Routine servicing and like-for-like repairs are part of maintenance and your annual statement, not a reason for a new certificate (FRNSW).
So if someone tells you a new extinguisher, a replaced exit light or a serviced hose reel needs a fresh certificate, push back and ask why. If the work changes what’s on your schedule, that’s different, and it’s worth checking with your certifier first.
Step-By-Step For Owners
- Find your fire safety schedule. It lists the measures both documents cover.
- Before building work, ask who will check the new measures. If the certificate falls on or after 13 February 2027, make sure that person is accredited.
- At completion, get the Fire Safety Certificate issued on the NSW Government template, with the assessment done within three months before.
- Send a copy to FRNSW with the current schedule. FRNSW takes it by email at firesafety@fire.nsw.gov.au and doesn’t charge a fee.
- Display the certificate and schedule prominently in the building.
- Diarise the first AFSS for within 12 months of the certificate date, and book the accredited practitioner for early in the three-month window.
- Fix any defects, then issue and lodge the AFSS with council and FRNSW, and display it.
Source: Planning NSW – Template & Timing
Source: FRNSW – Lodgement & Display
Source: Mosman Council – First AFSS
Source: SSC – AFSS lodgement
We handle both sides: checking newly installed measures for a Fire Safety Certificate, then running the annual fire safety statement each year after.
Regular inspections help identify these issues before they develop into major compliance problems.
Final Thoughts
Treat the Fire Safety Certificate as the start of the cycle, not the end of the job. It gets you the occupation certificate, and it also sets the date your first annual statement is due. Most problems we see come from owners who filed the certificate and forgot the clock it started.
If you’ve got building work coming up after February 2027, ask about accreditation now, not at handover.
LIKE TO KNOW MORE?
Schedule A FREE Discovery Call
Frequently Asked Questions (FAQ)
No. A Fire Safety Certificate is issued once, when building work involving fire safety measures is complete. An annual fire safety statement is issued every year after that for the existing building.
The building owner, or someone on the owner’s behalf, issues it. A properly qualified person chosen by the owner checks the measures first. From 13 February 2027, or earlier if an accreditation scheme is approved sooner, that person must be accredited to certify newly installed measures.
You need one when building work involving fire safety measures is completed, before an occupation certificate can be issued. Councils also require one after works under a fire safety order and on a change of use. Routine servicing doesn’t trigger one.
Within 12 months of the date the Fire Safety Certificate was issued. After that, each statement is due within 12 months of the previous one, and the assessment must happen within the three months before it’s issued.
It’s the certificate issued when building work or a change of use is complete. In staged projects, a final certificate can be issued for part of a building.
Councils disagree. Burwood Council says they’re no longer permissible because interim occupation certificates stopped after 2020, while Lake Macquarie Council still describes them. If your project is staged, ask your principal certifier which certificate applies.
The owner sends a copy to Fire and Rescue NSW with the current fire safety schedule, by email to firesafety@fire.nsw.gov.au, at no charge. Council receives a copy when the principal certifier determines the occupation certificate. The certificate and schedule must also be displayed in the building.
Yes. The certificate covers the new work at completion. The annual statement is still required every year for the building’s essential fire safety measures.
Important Disclaimer: This article is general in nature and does not constitute legal or compliance advice. Always consult a licensed fire safety practitioner and review relevant legislation for your property classification.
References:
Request a Free Quote
Get a no-obligation quote today—fast, easy, and completely free!