Complete 2026 Guide
An Annual Fire Safety Statement (AFSS) is a yearly declaration confirming a NSW building’s essential fire safety measures, extinguishers, hydrants, alarms, exit systems, have been assessed by an accredited practitioner and meet the required standard. Owners of buildings with a fire safety schedule must lodge it with council, Fire and Rescue NSW, as well as display it on-site.
Quick Summary
Miss your AFSS deadline and penalties start at $1,000 in week one and only escalate from there. This guide covers who needs one, who can sign it, what it costs, where to lodge it, and how the 2026 reforms change the rules for NSW owners.
Table Of Contents
If you own, manage or represent an owners corporation for a building in New South Wales that has fire safety measures like extinguishers, hydrants, alarms or emergency lighting, you’re almost certainly required to issue an Annual Fire Safety Statement (AFSS) every year. This guide covers what an AFSS is, which buildings need one, who is legally allowed to sign and assess it, how much it costs, where to lodge it, what happens if you miss the deadline, and what’s changing under NSW’s 2026 fire safety reforms.
Any Questions?
Our Experts Look Forward To Hearing From You!
What Is An Annual Fire Safety Statement (AFSS)?
An Annual Fire Safety Statement is a declaration from a building owner that the essential fire safety measures in their building “have been checked and continue to perform to the relevant standard.” It confirms that an accredited practitioner (fire safety) has assessed, inspected and verified the performance of each essential fire safety measure, and that the building’s exit systems have been inspected for compliance (NSW Department of Planning, Housing and Infrastructure).
The requirement is set out in the Environmental Planning and Assessment Act 1979 and the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021.
An AFSS is different from a Fire Safety Certificate (FSC). A Fire Safety Certificate is issued once, when a new or altered essential fire safety measure is first installed. An AFSS is issued every year after that, for as long as the building has essential fire safety measures (Fire & Rescue NSW).
| Fire Safety Certificate | Annual Fire Safety Statement | |
| When issued | Once, when a measure is first installed or altered | Every year, for as long as the building has essential fire safety measures |
| What it confirms | The new/altered measure meets its design standard | The measure continues to perform to standard |
| Who’s involved | Accredited practitioner, via the certifier at construction | Building owner (declaration) and accredited practitioner (assessment) |
Ready To Discuss Your Requirements?
Our Experts Look Forward To Hearing From You!
Which Buildings Need An AFSS?
The requirement applies to existing Class 1b to Class 9 buildings (under the Building Code of Australia classification system) that have essential fire safety measures specified in a fire safety schedule.
In practice, this covers most buildings other than standalone houses (Class 1a): apartment buildings, strata and mixed-use developments, offices, retail and hospitality premises, warehouses, schools, health and aged-care facilities, and industrial sites.
Buildings approved before 1 July 1988 are generally only caught if a development approval, construction certificate, complying development certificate or fire safety order has been issued for the building since that date (FPAA).
If you’re not sure whether your building is required to hold an AFSS, your fire safety schedule (held by the building owner, or available from council) will confirm it but it’s recommended you engage a certified fire safety professional to remove any uncertainty and confirm your compliance requirements.
Do You Need An AFSS? Quick Check
| Building scenario | AFSS required? |
| Apartment, strata or mixed-use building with a fire safety schedule | Yes |
| Office, retail, hospitality, warehouse, school or health/aged-care building with essential fire safety measures | Yes |
| Standalone house (Class 1a) | No |
| Approved before 1 July 1988, with no alterations or orders since | Generally no |
| Approved before 1 July 1988, but altered or ordered since that date | Yes |
| No essential fire safety measures listed on the building’s schedule | No |
Want To Know More?
Our Experts Look Forward To Hearing From You!
What Are “Essential Fire Safety Measures”?
Essential fire safety measures are the specific fire safety systems and features listed in a building’s fire safety schedule. Common examples include portable fire extinguishers, fire hydrants and hose reels, sprinkler systems, fire detection and alarm systems, emergency and exit lighting, exit signage, and fire-resisting (passive) construction elements (NSW Department of Planning, Housing and Infrastructure).
Each measure must be assessed against the standard set out in the building’s fire safety schedule, or where no schedule specifies a standard, against the standard to which it was originally designed and installed (FPAA).
Who Can Issue & Sign An AFSS?
There are two separate roles, and it’s a common point of confusion:
| Role | Who | Responsibility |
| Signs the declaration | Building owner, or an authorised agent (e.g. strata manager) | Issues the statement as the formal declaration |
| Assesses the measures | Accredited practitioner | Inspects, tests and endorses each essential fire safety measure |
| Cannot be combined | — | The practitioner who assessed the measures cannot also sign the owner’s declaration for that statement |
- The building owner (or their authorised agent) signs the declaration. This can be an individual, a company, an owners corporation, or someone acting on their behalf such as a strata manager or authorised employee (NSW Department of Planning, Housing and Infrastructure).
- An accredited practitioner (fire safety), often called an APFS, must assess, inspect and endorse each essential fire safety measure. This requirement for assessments to be carried out by a competent, accredited fire safety practitioner has applied since 1 October 2017 (City of Sydney).
Importantly, the person who signs the owner’s declaration cannot be the same accredited practitioner who assessed the fire safety measures listed in that statement This is a built-in conflict-of-interest safeguard (FPAA).
You can find an accredited practitioner (fire safety) via Fire Protection Association Australia, which Fire and Rescue NSW points building owners to for this purpose (Fire & Rescue NSW).
A separate accreditation change is coming, but it isn’t for AFSS assessments. From 13 February 2027 (or 18 months after an approved accreditation scheme is published, whichever occurs first), building owners will need to use an accredited person to certify newly installed fire safety measures for Fire Safety Certificates. It doesn’t replace or change the existing APFS requirement for annual statements described above (NSW Gov).
Ready To Discuss Your Requirements?
Our Experts Look Forward To Hearing From You!
How The AFSS Process Works
- Check The Fire Safety Schedule – for the building to confirm which essential fire safety measures apply.
- Engage An Accredited Practitioner (fire safety) – to assess and test each measure. This assessment must be carried out within the three months before the statement is submitted (Cootamundra Gundagai Regional Council)
- Rectify Any Defects – identified during the assessment before the statement is finalised.
- Complete The Statement – using the approved NSW Government template (NSW Department of Planning, Housing & Infrastructure)
- The Owner (or authorised agent) Signs The Declaration.
- Display A Copy Prominently In The Building – alongside the current fire safety schedule (NSW Department of Planning, Housing & Infrastructure)
- Lodge The Statement – with the local council and with the Commissioner of Fire and Rescue NSW (see below).
How Much Does An AFSS Cost?
There’s no fixed government fee for the AFSS itself, most NSW councils and Fire and Rescue NSW accept lodgement at no charge, though some councils charge a small administration fee for processing submissions, it’s worth checking with your local council.
The real cost driver is the accredited practitioner’s inspection and assessment work, plus any rectification of defects found along the way. This varies significantly with the size of the building, the number and type of essential fire safety measures on the schedule, and whether any measures are found to be non-compliant. Because of this variation, the most accurate way to understand your cost is a building-specific quote rather than a rule-of-thumb figure. This is something our team at Essential Asset & Fire’s AFSS service can provide you based on your fire safety schedule.
Where & How To Lodge Your AFSS
A copy of the completed statement must be given to your local council and to the Commissioner of Fire and Rescue NSW.
Fire and Rescue NSW accepts AFSS submissions electronically through its online lodgement form. If you need help with lodgement, FRNSW’s fire safety team have published a guide with links to their online portal which can be accessed via this link “Lodge a fire safety statement“.
Councils vary in how they accept lodgement, some by email, some by post, and some through an online portal, so check your specific council’s process (for example, City of Sydney accepts lodgement by email, post or in person.
Any Questions?
Our Experts Look Forward To Hearing From You!
AFSS Deadlines: The 12-Month Cycle
An AFSS must be issued within 12 months of the date the previous statement was given, or within 12 months of a Fire Safety Certificate being issued for a new or altered measure (City of Sydney).
Because the accredited practitioner’s assessment has to fall within the three months before you submit the statement, it’s worth starting the process well ahead of your due date as leaving it to the last minute increases the risk of a defect being found with no time left to rectify it before the deadline (Cootamundra Gundagai Regional Council).
Penalties For Late Or Missing AFSS
Non-compliance carries real financial and legal risk, and the penalties escalate the longer a statement is outstanding.
Late Lodgement Penalty Notices – increase week by week: $1,000 in the first week overdue, a further $2,000 in the second week, a further $3,000 in the third week, and a further $4,000 from the fourth week onward (City of Sydney).
Further Prosecution Costs – through The Land & Environment Court Can Carry Much Larger Penalties, but published sources disagree materially on the exact ceiling, and we could not confirm a single figure directly against the current legislation. Figures found in council and industry sources include $110,000 (City of Sydney) and, for continuing offences, up to $5,000,000 for corporations (plus $50,000 for each additional day) and up to $1,000,000 for individuals (plus $10,000 per additional day) (Wollongong City Council).
Additional Penalties – The below can also apply, depending on the situation:
- Failing To Maintain Essential Fire Safety Measures: up to $3,000 for an individual, $6,000 for a corporation
- Failing To Have Measures Inspected & Verified: up to $1,500 for an individual, $3,000 for a corporation
- Failing To Give Council A Statement: up to 400 penalty units for an individual, 800 penalty units for a corporation (indicatively $44,000–$88,000, depending on the current penalty unit value) (NSW Legislation – Environmental Planning and Assessment) & (NSW Legislation – Crimes Sentencing Procedure)
Penalties At A Glance
| Offence | Individual | Corporation | Source |
| Late lodgement (weekly penalty notice) | $1,000–$4,000+, escalating weekly | $1,000–$4,000+, escalating weekly | City of Sydney |
| Failing to maintain essential fire safety measures | Up to $3,000 | Up to $6,000 | FPA Australia GPG-04 |
| Failing to have measures inspected/verified | Up to $1,500 | Up to $3,000 | FPA Australia GPG-04 |
| Failing to give council a statement | Up to 400 penalty units (≈$44,000) | Up to 800 penalty units (≈$88,000) | FPA Australia GPG-04 |
Beyond direct fines, non-compliance can also affect building insurance and expose owners to a council-issued Fire Safety Order, Wollongong City Council, for example, states it may issue a Fire Safety Order where an AFSS has not been submitted on time. If you’ve received one, see our guide on what to do if you receive a council fire order.
Want To Know More?
Our Experts Look Forward To Hearing From You!
The February 2026 NSW Fire Safety Reforms: What’s Actually Changed
NSW’s fire safety framework is being progressively reformed, and it’s easy to conflate the different dates. Here’s what’s actually changing, and when, sourced directly from the NSW Government’s Building Commission.
- From 13 February 2026, essential fire safety measures in Class 1b to Class 9 buildings must be maintained in accordance with AS 1851-2012, the Australian Standard for servicing fire protection equipment and systems. This date was deferred from an original commencement of 13 February 2025.
- From 13 February 2027 (or 18 months after the new accreditation scheme is approved), building owners will need to use an accredited person to certify newly installed fire safety measures for Fire Safety Certificates, a new accreditation scheme, separate from the existing AFSS assessment requirement.
2017–2027 Reform Timeline
| Date | What changes | Applies to |
| Since 1 October 2017 | Accredited practitioner must assess AFSS measures (not new) | All buildings with an AFSS |
| From 13 February 2026 | Essential fire safety measures must be maintained per AS 1851-2012 | Class 1b–9 buildings |
| From 13 February 2027 (or +18 months from scheme approval) | Newly installed measures must be certified by a newly accredited person | New or altered essential fire safety measures |
For the full details on these reforms and what they mean for your building, see our dedicated article, NSW Fire Safety Regulation Changes: What’s New for 2026.
Ready To Discuss Your Requirements?
Our Experts Look Forward To Hearing From You!
AFSS For Strata & Commercial Buildings
In a strata scheme, the owners corporation is generally responsible for maintaining essential fire safety measures on common property, while individual lot owners are typically responsible for any measures within their own lot. Strata managers commonly coordinate the AFSS process on the owners corporation’s behalf, working with an accredited practitioner for the assessment.
For a full breakdown of strata-specific obligations, testing schedules and responsibility splits, see our guide: Fire Protection Requirements for Strata Buildings in Australia.
Final Thoughts
An Annual Fire Safety Statement isn’t just an annual compliance task, it’s the mechanism that confirms your building’s fire safety measures will actually work if they’re ever needed.
Buildings that treat AFSS as an ongoing 12-month cycle, rather than a once-a-year scramble are the ones that avoid penalty notices and last-minute defect surprises. If you’re unsure where your building stands, your fire safety schedule is the best place to start.
Essential Asset & Fire manages the full AFSS process for commercial, strata and residential buildings across Sydney, the Hunter, Newcastle, Lake Macquarie and the Central Coast, from accredited practitioner assessment through to council and Fire and Rescue NSW lodgement. Get a compliance quote for your building or talk to our team about your due date.
LIKE TO KNOW MORE?
Schedule A FREE Discovery Call
Frequently Asked Questions (FAQ)
No. A Fire Safety Certificate is issued once, when a new or altered essential fire safety measure is first installed. An AFSS is issued every year after that, confirming the measures continue to perform.
Yes, if the building has essential fire safety measures listed in a fire safety schedule, which applies to most multi-unit residential buildings.
The building owner must display a current copy prominently in the building, alongside the fire safety schedule.
No. The practitioner who assessed the fire safety measures cannot be the person who signs the owner’s declaration for that same statement.
You risk escalating weekly penalty notices, a potentially much larger penalty if the matter proceeds to prosecution, potential insurance complications, and a council-issued Fire Safety Order. See the Penalties section above for the full breakdown and a note on why we’re not quoting a single “maximum penalty” figure.
Fire and Rescue NSW directs building owners to Fire Protection Association Australia to locate an accredited practitioner.
Important Disclaimer: This article is general in nature and does not constitute legal or building compliance advice. Always consult a licensed fire safety practitioner and review relevant legislation for your property classification.
References:
Request a Free Quote
Get a no-obligation quote today—fast, easy, and completely free!

